Click menu access control.
2. Click and expand "Other Functions", and click "Area Anti Sneak Back".
3. The area anti sneak back function is that multiple control boards form an area in which the card must be swiped in before it can be swiped out.
4. For example: door a of a control board swipes the card to enter the door. Then door B of control board B swipes the card again and will not enter. The card must be swiped out at the door in the area.
5. When this function is realized, the slave and the host work together, and the host is responsible for registering the access status of all cards in the area. The slave machine is responsible for processing the card reading, detecting whether the card has been registered in the local machine and verifying the door opening authority, requesting the host machine to verify the access status, and opening the door for release after passing the verification.
6. Click the "Add" button.
7. Enter area name.
8. Click "Add Door" to add an area anti sneak back door prohibition device.
9. A master controller must be set for the selected equipment.
10. After the setting is successful, click "OK" to add the anti sneak back area.