中文
32.32. How to set area interlock
2022-01-13 10:49

  1. Click menu access control.


2. Click and expand "Other Functions", and click "Area Interlock".


3. The area interlock function is that multiple control boards form an area. When requesting to open the door in this area, all doors must be closed and the door can be opened only when it has been locked.


4. The master slave mode is used here. The master is responsible for recording the door status and electric lock output status of all points. The slave is responsible for handling the authorization authentication of door opening, closing and door opening requests, and requesting the host to verify the door opening request.


5. In the interlock state, automatic normally open, card swiping normally open, remote normally open, button normally open, relay mode disable bistable mode and other functions are automatically disabled.


6. Click the "Add" button.


7. Enter the area interlock name.


8. Click "Add Door" to add interlocking access control equipment.


9. Add the equipment that needs to set the interlocking area to the right column.


10. Check a device access control, and click the "Set as master controller" button to set the device as the master controller (only one master controller can be set).


11. After setting, click "OK" to add the interlocking area.